AHRI ACHC OM -  January 2012
This manual supersedes Forced-Circulation Air-Cooling and Air-Heating Coils Operations Manual, February 2002.

Appendix A. Data Sheets
  1. Form ACHC-DS1, ACHC Certification Program Data Submittal. Complete this worksheet to provide information and data for each model certified shall be published in the Directory.
  2. Form ACHC-DS2, Coil Inputs Submittal. Use this form for the following:
    • Authorization to Test and Coil Requisition
    • Challenge Test
    • Qualification of new BMG
    • Request for Verification.  
  3. Form ACHC-DS3, Re-rate Check Worksheet. Complete and return this worksheet when submitted software revised after a re-rate.
Appendix D. 410 Forms
  1. Form 410-1, Calculation Procedure To Determine Fin Efficiencies and Metal Thermal Resistance
  2. Form 410-2, Calculation of Air-Side Resistances from Steam and Water Coil Tests
  3. Form 410-3, Calculation of Tube-Side Pressure Drops from Steam and Water Coil Tests
  4. Form 410-4, Calculation of Refrigerant-Side Thermal Resistances from Volatile Refrigerant Coil Tests
  5. Form 410-5, Suggested Form for Rating Calculation Procedure for Sensible Heat Air Coils
  6. Form 410-6, Suggested Form for Rating Calculation Procedure for Cooling and Dehumidifying Coils
  7. Form 410-7, Calculation  of Heat Transfer Coefficient and Friction Factor for Ethylene Glycol Coils
  8. Form 410-8, Suggested Form for Rating Calculation Procedure for Sensible Heat Air Coils with Ethylene Glycol Solutions
  9. Form 410-9, Suggested Form for Rating Calculation Procedure for Cooling and Dehumidifying Coils with Ethylene Glycol Solutions

Superseded ACHC OM – February 2002.  Refer to this Product-Specific OM for information regarding testing prior to 2012. 

General Operations Manual
ACHC program flyer (English)
ACHC program flyer (Chinese)



Program Scope
This program applies to Forced-Circulation Air-Cooling Coils under non-frosting conditions and Forced-Circulation Air-Cooling and Air-Heating Coils only intended for:
  • Field installation (built-up systems and duct-mounted coils); and
  • Use in central station air-handling units.

Certified Ratings
  • Average total cooling or heating capacity, Btu/h [W]
  • Air pressure drop through coil at standard air density, in H2O [kPa]
  • Water, aqueous ethylene or propylene glycol solutions pressure drop through coil (including headers) at average fluid density, ft of fluid [m of fluid]


The rules and procedures for obtaining and maintaining certification are detailed in the Resources section above. The specific Standard listed above details the technical requirements for rating and publishing your product performance, the AHRI General Operations Manual (OM) details the program operational rules that are generic to all of AHRI’s certification programs and lastly, the Product-specific Operations Manual provides the operational rules that are specific to this program along with the required documents and fees. Please ensure that you are familiar with the latest rules and procedures for this program.