Member Login
|
Newsletter Signup
|
Search Standards
|
Contact Us
{1}
##LOC[OK]##
{1}
##LOC[OK]##
##LOC[Cancel]##
{1}
##LOC[OK]##
##LOC[Cancel]##
Certification
AHRI Certification Programs
Learn About Certification
Promoting Certification
Certification Participant Profile
ENERGY STAR
Standards
HVACR Industry Standards
HVACR Industry Guidelines
Standards Process
Standards Development Organizations
Contractors & Specifiers
Directory of Certified Product Performance
HVACR Equipment/Components
HVACR Replacement Guidance
Homeowners
Federal Energy Efficiency Tax Credits
Indoor Comfort Systems
How Things Work
Improve Safety
Save Energy
Technical Definitions and Terms
Advocacy
Federal Legislative
Federal Regulatory
State Legislative
Building Codes
Global Policies
Climate Change
Resources
Statistics
Research
Global Resources
HVACR Education and Training
HVACR & Mechanical Conference
Equipment Donations
Terms and Technical Definitions
News & Events
Press Releases
Monthly Shipping Releases
AHRI in the News
Communications
Meetings and Events
Political News Links
Public Affairs Contacts
About Us
HVACR & Water Heating Products
AHRI Members
Join AHRI
Contact Us
Visit AHRI
Career Opportunities
Annual Reports
Privacy Policy
AHRI Staff
Standards
HVACR Industry Standards
HVACR Industry Guidelines
Standards Process
Standards Development Organizations
Edit link
{1}
##LOC[OK]##
{1}
##LOC[OK]##
##LOC[Cancel]##
{1}
##LOC[OK]##
##LOC[Cancel]##
News & Features
News
Events
Resources
AHRI Announces New Logo and ...
The Air-Conditioning, Heating, and Refrigeration Institute (AHRI) today debuted a ...
More >
AHRI Releases March 2013 U.S. ...
A full report of the March, 2013 monthly shipments is ...
More >
AHRI Certification Programs Achieve Exemplary ...
The Air-Conditioning, Heating, and Refrigeration Institute (AHRI) today announced that ...
More >
AHRI's 2012 Annual Meeting
AHRI Welcomes New Officers, Presents Awards and Scholarships ...
More >
AHRI 2013 Spring Meeting
Please join us for the 2013 Spring Meeting in Arlington, ...
More >
Meetings and Events Calendar
More >
Terms and Technical Definitions
AFUE Annualized Fuel Utilization Efficiency (AFUE) is a measure ...
More >
HVACR & Mechanical Conference
Formerly the HVACR & Mechanical Instructor Workshop ...
More >
Global Resources
AHRI is an active participant in global activities regarding policy, ...
More >
BECOME A MEMBER
AHRI membership provides your company with the latest policy initiatives, legislative and regulatory activities, industry standards and statistical reports, global opportunities, and much more.
Home
>
Standards
>
HVACR Industry Guidelines
HVACR Industry Guidelines
AHRI Guideline A: Energy Management Systems and Load Management Through Duty Cycling (2008)
Program Scope
This provides general precautionary guidelines for customers, building owners, and others that install energy management systems (EMS) as add-on after market applications to refrigeration and air-conditioning equipment.
Free Download:
AHRI Guideline A-2008
© 2008, by Air-Conditioning, Heating and Refrigeration Institute
AHRI Guideline B: Roof Mounted Outdoor Air-Conditioner Installations (1997)
Program Scope
This document establishes guidelines for the installation of roof mounted outdoor air-conditioner equipment and sets forth good construction practices covering curb and roof penetrations and sealings. This guideline is a joint publication with the Sheet Metal and Air-Conditioning Contractors' National Association, Inc. (SMACNA).
Free Download:
AHRI Guideline B-1997
© 1997, by Air-Conditioning, Heating and Refrigeration Institute
AHRI Guideline E: Fouling Factors: A Survey of Their Application in Today's Air-Conditioning and Refrigeration Industry (1997)
Program Scope
This guideline addresses the influence of fouling of heat transfer surfaces as it affects water-chilling evaporators and water-cooled condensers. It describes fouling factor allowances applied to centrifugal and rotary screw water chilling packages, positive displacement compressor water chilling packages, as well as absorption water chilling and water heating packages in ARI Standards 550/590 and 560.
Free Download:
AHRI Guideline E-1997
© 1997, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI Guideline F: Selection, Installation and Servicing of Residential Humidifiers (2008)
Program Scope
This guideline provides sizing, selection, installation, and servicing recommendations for central system (furnace-mounted) humidifiers and for self-contained humidifiers, installed in residential and small commercial applications.
Free Download:
AHRI Guideline F-2008
© 2008, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI Guideline G (I-P)-2011, Mechanical Balance of Fans and Blowers
Program Scope
This guideline applies specifically to system vibration and mechanical balancing as related to fans and blowers. The principles presented, however, can be generally applied to many rotating components.
Free Download:
AHRI Guideline G (I-P)-2011
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI Guideline G (SI)-2011, Mechanical Balance of Fans and Blowers
Program Scope
This guideline applies specifically to system vibration and mechanical balancing as related to fans and blowers. The principles presented, however, can be generally applied to many rotating components.
Free Download:
AHRI Guideline G (SI)-2011
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI Guideline K: Containers for Recovered Non-Flammable Fluorocarbon Refrigerants (2009)
Product Scope
This guideline applies to cylinders with a maximum service pressure of 400 psig and ton containers with a service pressure of 500 psig for the receipt, storage and transportation of recovered non-flammable fluorocarbon refrigerants.
Free Download:
AHRI Guideline K-2009
© 2009, by Air-Conditioning, Heating and Refrigeration Institute
AHRI Guideline N: Assignment of Refrigerant Container Colors (2012)
Program Scope
This guideline publishes industry accepted, refrigerant specific color assignments for refrigerant containers and provides procedures for chemical producers to request color assignments for new refrigerants that are produced in significant quantities.
Free Download:
AHRI Guideline N-2012
© 2008, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI Guideline Q-2010: Content Recovery and Proper Recycling of Refrigerant Cylinders
Program Scope
This guideline is applicable to all Department of Transportation (DOT) Non-Refillable and Refillable Fluorocarbon Refrigerant Cylinders, as defined in Section 3, having water capacity greater than 8 pounds, used to transport refrigerants sold in the United States.
Free Download:
AHRI Guideline Q-2010
© 2010, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI Guideline T: Specifying the Thermal Performance of Cool Storage Equipment (2002)
Program Scope
The purpose of this guideline is to establish for cool storage equipment, the minimum information required for: (1) user specified application requirements, and (2) supplier specified thermal performance data.
Free Download:
AHRI Guideline T-2002
© 2002, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI Guideline V (I-P)-2011: Calculating the Efficiency of Energy Recovery Ventilation and Its Effect on Efficiency and Sizing of Building HVAC Systems
Program Scope
The purpose of this guideline is to establish a method of calculating the energy efficiency of applied Energy Recovery Ventilation components and of heating, ventilating, and/or air-conditioning systems utilizing such components at selected operating conditions. It also provides guidance on proper sizing of cooling and heating equipment when such energy recovery components are applied.
Free Download:
AHRI Guideline V (I-P)-2011
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI Guideline V (SI)-2011: Calculating the Efficiency of Energy Recovery Ventilation and Its Effect on Efficiency and Sizing of Building HVAC Systems
Program Scope
The purpose of this guideline is to establish a method of calculating the energy efficiency of applied Energy Recovery Ventilation components and of heating, ventilating, and/or air-conditioning systems utilizing such components at selected operating conditions. It also provides guidance on proper sizing of cooling and heating equipment when such energy recovery components are applied.
Free Download:
AHRI Guideline V (SI)-2011
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI Guideline W: Selecting, Sizing, & Specifying Packaged Air-To-Air Energy Recovery Ventilation Equipment (2005)
Program Scope
The purpose of this guideline is to provide information to support the application of Air-to-Air Energy Recovery Ventilation Equipment (AAERVE). This guideline supports AAERVE that is manufactured using Air-to-Air Heat Exchangers (energy recovery components) rated in accordance with ARI Standard 1060. These recovery components include Heat Pipe Heat Exchangers, Plate Heat Exchangers, and Rotary Heat Exchangers.
Free Download:
AHRI Guideline W-2005
© 2005, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI Guideline X-2009: Induced Draft Furnace Heat Exchanger Inspection
Program Scope
This guideline applies to the inspection of induced draft furnace heat exchangers.
Free Download:
AHRI Guideline X-2009
© 2009, by Air-Conditioning, Heating and Refrigeration Institute