Member Login
|
Newsletter Signup
|
Search Standards
|
Contact Us
{1}
##LOC[OK]##
{1}
##LOC[OK]##
##LOC[Cancel]##
{1}
##LOC[OK]##
##LOC[Cancel]##
Certification
AHRI Certification Programs
Learn About Certification
Promoting Certification
Certification Participant Profile
ENERGY STAR
Standards
HVACR Industry Standards
HVACR Industry Guidelines
Standards Process
Standards Development Organizations
Contractors & Specifiers
Directory of Certified Product Performance
HVACR Equipment/Components
HVACR Replacement Guidance
Homeowners
Federal Energy Efficiency Tax Credits
Indoor Comfort Systems
How Things Work
Improve Safety
Save Energy
Technical Definitions and Terms
Advocacy
Federal Legislative
Federal Regulatory
State Legislative
Building Codes
Global Policies
Climate Change
Resources
Statistics
Research
Global Resources
HVACR Education and Training
HVACR & Mechanical Conference
Equipment Donations
Terms and Technical Definitions
News & Events
Press Releases
Monthly Shipping Releases
AHRI in the News
Communications
Meetings and Events
Political News Links
Public Affairs Contacts
About Us
HVACR & Water Heating Products
AHRI Members
Join AHRI
Contact Us
Visit AHRI
Career Opportunities
Annual Reports
Privacy Policy
AHRI Staff
Standards
HVACR Industry Standards
Search Standards
Withdrawn Standards and Guidelines
Proposed Standards and Guidelines
Superseded AHRI (ARI) Standards Referenced
in US Regulations
HVACR Industry Guidelines
Standards Process
Standards Development Organizations
Edit link
{1}
##LOC[OK]##
{1}
##LOC[OK]##
##LOC[Cancel]##
{1}
##LOC[OK]##
##LOC[Cancel]##
News & Features
News
Events
Resources
AHRI Announces New Logo and ...
The Air-Conditioning, Heating, and Refrigeration Institute (AHRI) today debuted a ...
More >
AHRI Releases March 2013 U.S. ...
A full report of the March, 2013 monthly shipments is ...
More >
AHRI Certification Programs Achieve Exemplary ...
The Air-Conditioning, Heating, and Refrigeration Institute (AHRI) today announced that ...
More >
AHRI's 2012 Annual Meeting
AHRI Welcomes New Officers, Presents Awards and Scholarships ...
More >
AHRI 2013 Spring Meeting
Please join us for the 2013 Spring Meeting in Arlington, ...
More >
Meetings and Events Calendar
More >
Terms and Technical Definitions
AFUE Annualized Fuel Utilization Efficiency (AFUE) is a measure ...
More >
HVACR & Mechanical Conference
Formerly the HVACR & Mechanical Instructor Workshop ...
More >
Global Resources
AHRI is an active participant in global activities regarding policy, ...
More >
BECOME A MEMBER
AHRI membership provides your company with the latest policy initiatives, legislative and regulatory activities, industry standards and statistical reports, global opportunities, and much more.
Home
>
Standards
>
HVACR Industry Standards
>
Search Standards
Search Standards
AHRI 220-2012: Reverberation Room Qualification and Testing Procedures for Determining Sound Power of HVAC Equipment
Standard Scope
This standard provides the methodology for the determination of Sound Power Levels of noise sources that emit Broadband Sound and/or Discrete Frequency Sounds/Tones in reverberation rooms.
Free Download:
AHRI Standard 220-2012
©2012 Air-Conditioning, Heating, and Refrigeration Institute
AHRI 260 (I-P)-2012: Sound Rating of Ducted Air Moving and Conditioning Equipment
Standard Scope
This standard applies to Ducted Equipment and specifies the methods for the determination of the sound power rating of the indoor sections of factory-made residential, commercial and industrial air-conditioning and Heat Pump equipment, which are electrically driven, with mechanical compression and containing fans, using mapped sound data for rating the various product Sound Components.
Free Download:
AHRI Standard 260 (I-P)-2012
© 2012, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 261 (SI)-2012: Sound Rating of Ducted Air Moving and Conditioning Equipment
Standard Scope
This standard applies to Ducted Equipment and specifies the methods for the determination of the sound power rating of the indoor sections of factory-made residential, commercial and industrial air-conditioning and Heat Pump equipment, which are electrically driven, with mechanical compression and containing fans, using mapped sound data for rating the various product Sound Components.
Free Download:
AHRI Standard 261 (SI)-2012
© 2012, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 320-1998: Water-Source Heat Pumps
Standard Scope
This standard establishes a single set of requirements for the testing and rating of cooling and heating capacities and energy efficiency ratios (EER's for cooling and COP's for heating) for water-source heat pumps; whereby, equipment performance ratings can be compared from product to product.
Free Download:
AHRI Standard 320-1998
©1998, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 325-1998: Ground Water-Source Heat Pumps
Standard Scope
This standard establishes a single set of requirements for the testing and rating of cooling and heating capacities and energy efficiency ratios (EER's for cooling and COP's for heating) at selected fluid flow rates for ground water-source heat pumps; whereby, equipment performance ratings can be compared from product to product.
Free Download:
AHRI Standard 325-1998
©1998, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 330-1998: Ground Source Closed-Loop Heat Pumps
Standard Scope
This standard establishes a single set of requirements for the testing and rating of cooling and heating capacities and energy efficiency ration (EER's for cooling and COP's for heating) at selected fluid flow rates for ground source closed-loop heat pumps; whereby, equipment performance ratings can be compared from product to product.
Free Download:
AHRI Standard 330-1998
©1998, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 410-2001 with Addenda 1, 2 and 3: Forced-Circulation Air-Cooling and Air-Heating Coils
Standard Scope
This standard establishes a single set of testing and rating requirements for determining capacities, air side frictions, and tube side frictions of forced-circulation air-cooling and air-heating coils; whereby, equipment performance ratings can be compared from product to product.
Free Download:
AHRI Standard 410-2001 with Addenda 1, 2, and 3
© 2001, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 450-2007: Water-Cooled Refrigerant Condensers, Remote Type
Standard Scope
This standard establishes a single set of testing and rating requirements for determining heat rejection and water pressure drop for remote type, water-cooled refrigerant condensers; whereby, equipment performance ratings can be compared from product to product.
Free Download:
AHRI Standard 450-2007
© 2007, by Air-Conditioning, Heating and Refrigeration Institute
AHRI 480-2007: Remote Type Refrigerant-Cooled Liquid Coolers
Standard Scope
This standard establishes a single set of requirements for the testing and rating of net refrigerating capacity and liquid pressure drop for remote-type refrigerant-cooled liquid coolers; whereby, equipment performance ratings can be compared from product to product.
Free Download:
AHRI Standard 480-2007
© 2007, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI Standard 570 (I-P)-2012: Performance Rating of Positive Displacement Carbon Dioxide Refrigerant Compressors and Compressor Units
Standard Scope
This standard applies to electric motor driven, single and variable capacity, single and two stage Positive Displacement Refrigerant Compressors and Compressor Units operating with carbon dioxide in both subcritical and transcritical applications for refrigeration. This standard also applies to the presentation of performance data for Positive Displacement Compressor and Compressor Units operating with carbon dioxide.
Free Download:
AHRI Standard 570 (I-P)-2012:
Performance Rating of Positive Displacement Carbon Dioxide Refrigerant Compressors and Compressor Units
© 2012, by Air-Conditioning, Heating and Refrigeration Institute
AHRI Standard 571 (SI)-2012: Performance Rating of Positive Displacement Carbon Dioxide Refrigerant Compressors and Compressor Units
Standard Scope
This standard applies to electric motor driven, single and variable capacity, single and two stage Positive Displacement Refrigerant Compressors and Compressor Units operating with carbon dioxide in both subcritical and transcritical applications for refrigeration. This standard also applies to the presentation of performance data for Positive Displacement Compressor and Compressor Units operating with carbon dioxide.
Free Download:
AHRI Standard 571 (SI)-2012: Performance Rating of Positive Displacement Carbon Dioxide Refrigerant Compressors and Compressor Units
© 2012, by Air-Conditioning, Heating and Refrigeration Institute
Program Scope
This standard establishes a single set of testing and rating requirements for determining capacities, energy efficiencies (power input per ton, EER, or COP), water pressure drop, IPLV (integrated part load value), and NPLV (non-standard part load value) for water chilling packages using the vapor compression cycle; whereby, equipment performance ratings can be compared from product to product. The standard applies to chilling packages including one or more hermetic or open drive compressors (centrifugal, rotary screw, scroll, reciprocating, or other types), equipped with either water-cooled, air-cooled, evaporative-cooled condensers or supplied without a condenser.
Free Download:
AHRI Standard 550/590-2003
Copyright 2003, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 700-2012: Specification for Fluorocarbon Refrigerants
Standard Scope
This standard specifies acceptable levels of contaminants (purity requirements) for fluorocarbon refrigerants (hereinafter referred to as refrigerants) regardless of source and lists acceptable test methods. These refrigerants are: R-11; R-12; R-13; R-22; R-23; R-32; R-113; R-114; R-115; R-116; R-123; R-124; R-125; R-134a; R-141b; R-142b; R-143a; R-152a; R-218; R-227ea; R-236fa; R-245fa; R-1234yf; R-1234ze(E); R-401A; R-401B; R-402A; R-402B; R-403A; R-403B; R-404A; R-405A; R-406A; R-407A; R-407B; R-407C; R-407D; R-407E; R-407F; R-408A; R-409A; R-409B; R-410A; R-410B; R-411A; R-411B; R-412A; R-413A; R-414A; R-414B; R-415A; R-415B; R-416A; R-417A; R-417B; R-418A; R-419A; R-420A; R-421A; R-421B; R-422A; R-422B; R-422C; R-422D; R-423A; R-424A; R-425A; R-426A; R-427A, R-428A, R-430A, R-434A, R-437A; R-438A; R-439A; R-440A; R-442A; R-500; R-502; R-503; R-507A; R-508A; R-508B; R-509A; and R-512A as referenced in the ANSI/ASHRAE Standard 34 with Addenda.
Free Download:
AHRI 700-2012:
Specification for Fluorocarbon Refrigerants
©2012, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 700C-2008: Appendix C to AHRI Standard 700-Analytical Procedures for AHRI Standard 700-06
Standard Scope
This Appendix specifies the associated methods of testing for acceptability of fluorocarbon refrigerants regardless of source (new, reclaimed and/or repackaged) for use in new and existing refrigeration and air-conditioning products
Free Download:
AHRI Standard 700C-2008
© 2008, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 700D-2012: Appendix D Gas Chromatograms for AHRI Standard 700-2012-Informative
Purpose
The purpose of this informative appendix is to provide figures for the gas chromatograms used with Appendix C, Analytical Procedures for AHRI Standard 700-2006-Normative.
Free Download:
AHRI 700D-2012:
Appendix D Gas Chromatograms for AHRI Standard 700-2012-Informative
© 2012, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 715-2007: Performance Rating of Liquid-Line Filters
Standard Scope
This standard applies to hermetic Liquid-line Filters designed for use in the liquid line of all types of refrigeration and air-conditioning systems employing refrigerants. This standard provides a means of determining the Overall Filter Efficiency and Contaminant Capacity of a Liquid-line Filter at specified conditions.
Free Download:
AHRI Standard 715-2007
© 2007, by the Air-Conditioning, Heating, and Refrigeration Institute
AHRI 740-1998: Refrigerant Recover/Recycling Equipment
Standard Scope
This standard establishes a single set of requirements for the testing and rating of capacity, speed, purge loss, and minimum purity requirements for refrigerants for refrigerant recovery/recycling equipment; whereby, equipment performance can be compared from product to product. The standard applies to equipment for recovering and/or recycling single compound refrigerants, azeotropes, zeotropic blends, and their normal contaminants from refrigerant systems.
Free Download:
AHRI Standard 740-1998
© 1998, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 810 (I-P)-2012: Performance Rating of Automatic Commercial Ice-Makers
Standard Scope
This standard applies to factory-made Automatic Commercial Ice-Makers as defined in Section 3.
Free Download:
AHRI Standard 810 (I-P)-2012
© 2012, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 811 (SI)-2012: Performance Rating of Automatic Commercial Ice-Makers
Standard Scope
This standard applies to factory-made Automatic Commercial Ice-Makers as defined in Section 3.
Free Download:
AHRI Standard 811 (SI)-2012
© 2012, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 840-1998: Unit Ventilators
Standard Scope
This standard establishes a single set of requirements for the testing and rating of cooling and heating capacities, power input, efficiency, standard air flow, fluid flow, and pressure drop for unit ventilators; whereby, equipment performance ratings can be compared from product to product.
Free Download:
AHRI Standard 840-1998
© 1998, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 885-2008 with Addendum 1: Procedure for Estimating Occupied Space Sound Levels in the Application of Air Terminals and Air Outlets
Standard Scope
This standard provides a consistent industry-accepted method for estimating sound pressure levels in a conditioned space for the application of air terminals and air outlets. Air terminals, air outlets, and the low pressure ductwork which connects them are considered as sound sources and are the subject of this standard. The method described in this Standard can be used to identify acoustically critical paths in the system design. The design effects of inserting alternative components and changes in the system can be evaluated.
Free Downloads:
AHRI Standard 885-2008 with Addendum
and
Duct Discharge Calculation Spreadsheet for AHRI Standard 885-2008
© 2008, by Air-Conditioning, Heating and Refrigeration Institute
AHRI 920-2012: Performance Rating of DX-Dedicated Outdoor Air System Units
Standard Scope
This standard applies to factory-assembled commercial or industrial DX-Dedicated Outdoor Air System Units
Free Download:
AHRI 920-2012:
Performance Rating of DX-Dedicated Outdoor Air System Units
© 2012, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 110-2012: Air-Conditioning, Heating and Refrigerating Equipment Nameplate Voltages
Standard Scope
This standard establishes a single set of electrical voltage rating and operating limit requirements for air-conditioning and refrigerating equipment. It presents the basic relationships between standard nominal system voltages and utilization voltages.
Free Download:
ANSI/AHRI Standard 110-2012: Air-Conditioning, Heating and Refrigerating Equipment Nameplate Voltages
© 2012, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 1110 (I-P)-2013: Performance Rating of Mechanical Transport Refrigeration Units
Standard Scope
This standard establishes a single set of requirements for the testing and rating of cooling capacities and electric standby cooling capacities for mechanical transport refrigeration units employing forced-circulation air-coolers; whereby, equipment performance ratings can be compared from product to product.
Free Download:
AHRI Standard 1110 (I-P)-2013
© 2013, by Air-Conditioning, Heating, and Refrigeration Institute
AHRI 1111 (SI)-2013: Performance Rating of Mechanical Transport Refrigeration Units
Standard Scope
This standard establishes a single set of requirements for the testing and rating of cooling capacities and electric standby cooling capacities for mechanical transport refrigeration units employing forced-circulation air-coolers; whereby, equipment performance ratings can be compared from product to product.
Free Download:
AHRI Standard 1111 (SI)-2013
© 2013, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 210/240-2008 with Addenda 1 and 2, Performance Rating of Unitary Air-Conditioning & Air-Source Heat Pump Equipment
Standard Scope
The purpose of this standard is to establish, for Unitary Air-Conditioners and Air-Source Unitary Heat Pumps: definitions; classifications; test requirements; rating requirements; minimum data requirements for Published Ratings; operating requirements; marking and nameplate data; and conformance conditions.
Free Download:
ANSI/AHRI Standard 210/240-2008 with Addenda 1 and 2,
Performance Rating of Unitary Air-Conditioning & Air-Source Heat Pump Equipment
© 2008, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 250-2008: Performance and Calibration of Reference Sound Sources
Standard Scope
This standard applies to all Reference Sound Sources used in conjunction with ARI sound rating standards and covers the one-third octave band frequency range from 50 to 10,000 Hz. This standard also includes calibration over a limited frequency range. Multiple Reference Sound Sources may be used to cover the entire frequency range from 50 to 10,000 Hz.
Free Download:
ANSI/AHRI Standard 250-2008
© 2008, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 270-2008: Sound Rating of Outdoor Unitary Equipment
Standard Scope
This standard establishes for the outdoor sections of air-conditioning and heat pump equipment of less than 135,000 Btuh, sound ratings in terms of a derived tone corrected A-weighted sound power level, in decibels.
Free Download:
ANSI/AHRI Standard 270-2008
© 2008, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 275-2010: Application of Sound Rating Levels of Outdoor Unitary Equipment
Standard Scope
This standard applies to the outdoor sections of factory made air-conditioning and heat pump equipment with cooling capacities up to 40kW, as shown in the scope of AHRI Standards 210/240 and 340/360 when rated in accordance with AHRI Standard 270.
Free Download:
ANSI/
AHRI Standard 275-2010
© 2010, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 280-2011: Requirements for the Qualification of Reverberation Rooms in the 63Hz Octave Band
Standard Scope
This standard applies to products rated in the 63 Hz Octave Band (50, 63 and 80 Hz One-Third Octave Bands) where the sound power is determined from measurements made in a reverberation room by using the comparison method as specified per ANSI Standard S12.51/ISO: 3741.
Free Download
:
ANSI/AHRI Standard 280-2011
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 300-2008: Sound Rating and Sound Transmission Loss of Packaged Terminal Equipment
Standard Scope
This standard establishes a method of sound rating both the indoor and outdoor portions of packaged terminal equipment in terms of octave band sound power levels, tone adjusted A-weighted sound power rating levels, and A-weighted sound power levels. Additionally, this standard establishes a method for determining single number sound transmission loss ratings for packaged terminal equipment.
Free Download:
ANSI/AHRI Standard 300-2008
© 2009, by Air-Conditioning, Heating and Refrigeration Institute
ANSI/AHRI/CSA 310/380-2004: Standard for Packaged Terminal Air-Conditioners and Heat Pumps (CSA-C744-04)
Standard Scope
This standard establishes a single set of requirements for the testing and rating of cooling and heating capacities and energy efficiency ratios (EER for cooling an COP for heating) for factory-assembled packaged terminal air-conditioners (PTAC's) and packaged terminal heat pumps (PTHP's) used in residential, commercial, and industrial systems; whereby, equipment performance ratings can be compared from product to product. Excluded are room air-conditioners.
Free Download:
ANSI/AHRI/CSA Standard 310/380-2004
© 2004, by Air-Conditioning and Refrigeration Institute
ANSI/AHRI 340/360-2007 with Addendum 2, Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment
Standard Scope
This standard applies to factory-made Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment as defined. This standard applies only to electrically operated, vapor compression refrigeration systems.
Free Download:
ANSI/AHRI Standard 340/360-2007 with Addendum 2,
Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment
© 2007, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 350-2008: Sound Rating of Non-Ducted Indoor Air-Conditioning Equipment
Standard Scope
This standard establishes a method of sound rating the indoor portions of non-ducted air-conditioning equipment in terms of octave band sound power levels, tone-adjusted A-weighted sound power levels, and A-weighted sound power levels. The standard applies to the indoor portions of non-ducted unitary equipment, packaged terminal equipment, and room fan-coil air-conditioners.
Free Download:
ANSI/AHRI Standard 350-2008
© 2008, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 365 (I-P)-2009: Commercial and Industrial Unitary Air-Conditioning Condensing Units
Standard Scope
This standard applies to factory-made Commercial and Industrial Unitary Air-Conditioning Condensing Units greater than or equal to 135,000 Btu/h as defined in Section 3. 2.1.1 Energy Source. This standard applies only to electrically-driven, mechanical compression-type condensing units.
Free Download:
ANSI/AHRI Standard 365 (I-P)-2009
Copyright 2009, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 366 (SI)-2009: Commercial and Industrial Unitary Air-Conditioning Condensing Units
Standard Scope
This standard applies to factory-made Commercial and Industrial Unitary Air-Conditioning Condensing Units greater than or equal to 40.0 kW as defined in Section 3. 2.1.1 Energy Source. This standard applies only to electrically-driven, mechanical compression-type condensing units.
Free Download
:
ANSI/AHRI Standard 366 (SI)-2009
© 2009, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 370-2011: Sound Performance Rating of Large Air-Cooled Outdoor Refrigerating and Air-Conditioning Equipment
Standard Scope
This standard applies to the outdoor portions of factory-made commercial and industrial Large Outdoor Refrigerating and Air-Conditioning Equipment, including heat pumps, used for refrigerating or air-conditioning of spaces, as defined in Section 3 of this standard.
Free Download:
ANSI/AHRI 370-2011:
Sound Performance Rating of Large Air-Cooled Outdoor Refrigerating and Air-Conditioning Equipment
© 2011 Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 390-2003: Performance Rating of Single Package Vertical Air-Conditioners and Heat Pumps
Standard Scope
This standard applies to factory-assembled commercial or industrial Single Package Vertical Air-Conditioner and Heat Pump equipment as defined.
Free Download:
ANSI/AHRI Standard 390-2003
© 2003, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 400-2001 with Addenda 1 and 2: Liquid to Liquid Heat Exchangers
Standard Scope
This standard establishes definitions, test requirements, minimum data requirements for Published Ratings, marking and nameplate data, and conformance conditions for liquid to liquid heat exchangers.
Free Download
:
ANSI/AHRI Standard 400-2001 with Addenda 1 and 2
© 2001, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 420-2008: Performance Rating of Forced-Circulation Free-Delivery Unit Coolers for Refrigeration
Standard Scope
This standard applies to factory-made, Forced-Circulation, Free-Delivery Unit Coolers operating with a Volatile Refrigerant fed by either direct expansion or liquid overfeed at wet and/or dry conditions.
Free Download:
ANSI/AHRI Standard 420-2008
© 2008, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 430-2009: Central Station Air Handling Units
Standard Scope
This standard establishes a single set of testing and rating requirements for determining fan speed (rpm) and brake horse power (bhp) at selected air flows (cfm's) and static pressures (inches of water) for central station air-handling units (which are encased assemblies consisting of a fan or fans); whereby, equipment performance ratings can be compared from product to product.
Free Download:
ANSI/AHRI Standard 430-2009
© 2009, by Air-Conditioning and Refrigeration Institute
ANSI/AHRI 440-2008: Performance Rating of Room Fan-Coils
Standard Scope
This standard establishes a single set of requirement for the testing and rating of total cooling capacity, sensible cooling capacity, and power input for room fan-coil air-conditioners and unit ventilators; whereby, equipment performance ratings can be compared from product to product.
Free Download:
ANSI/AHRI Standard 440-2008
© 2008, by Air-Conditioning, Heating and Refrigeration Institute
ANSI/AHRI 460-2005: Performance Rating of Remote Mechanical-Draft Air-Cooled Refrigerant Condensers
Standard Scope
This standard applies to remote mechanical-draft air-cooled refrigerant condensers as defined in Section 3 for use with or without external air resistance.
Free Download:
ANSI/AHRI Standard 460-2005
© 2005, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 470-2006: Performance Rating of Desuperheater/Water Heaters
Standard Scope
This standard applies to Desuperheater/Water Heaters supplied as separate components, as defined in Section 3 and using single component and azeotropic refrigerants only.
Free Download:
ANSI/AHRI Standard 470-2006
© 2006, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 490 (I-P)-2011: Remote Mechanical-Draft Evaporative Refrigerant Condensers
Standard Scope
This standard establishes a single set of requirements for the testing and rating of total heat rejection effect and fan or pump motor rated shaft output power for remote mechanical-draft evaporative refrigerant condensers; whereby, equipment performance ratings can be compared from product to product.
Free Download:
ANSI/AHRI Standard 490 (I-P)-2011
©2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 491 (SI)-2011: Remote Mechanical-Draft Evaporative Refrigerant Condensers
Standard Scope
This standard establishes a single set of requirements for the testing and rating of total heat rejection effect and fan or pump motor rated shaft output power for remote mechanical-draft evaporative refrigerant condensers; whereby, equipment performance ratings can be compared from product to product.
Free Download:
ANSI/AHRI Standard 491 (SI)-2011
©2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 495-2005: Performance Rating of Refrigerant Liquid Receivers
Standard Scope
This standard establishes a single set of requirements for the testing and rating of storage capacity for refrigerant liquid receivers; whereby, equipment performance ratings can be compared from product to product.
Free Download:
ANSI/AHRI Standard 495-2005
© 2005, by Air-Conditioning, Heating and Refrigeration Institute
ANSI/AHRI 510-2006: Performance Rating of Positive Displacement Ammonia Compressors and Compressor Units
Standard Scope
This standard applies to Positive Displacement Ammonia Compressors (Ammonia Compressors) and Compressor Units (Ammonia Compressor Units) for use in commercial and industrial refrigeration applications.
Free Download:
ANSI/AHRI Standard 510-2006
© 2006, by Air-Conditioning, Heating and Refrigeration Institute
ANSI/AHRI 520-2004: Performance Rating of Positive Displacement Condensing Units
Standard Scope
This standard establishes a single set of testing and rating requirements for determining capacity, power input, and EER for positive displacement condensing units for refrigeration applications; whereby, equipment performance ratings can be compared from product to product.
Free Download:
ANSI/AHRI Standard 520-2004
© 2004, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 530-2011, Rating of Sound and Vibration for Refrigerant Compressors
Standard Scope
This standard applies to External-drive, Hermetic and Semi-Hermetic Refrigerant Compressors. In the case of External-drive Refrigerant Compressors, the driving mechanism shall be excluded from the sound and vibration measurements. However, for Semi-Hermetic Refrigerant Compressors where the driving mechanism is an integral part of the compressor assembly as defined in Section 3, it shall be included in the measurements.
Free Download:
ANSI/AHRI Standard 530-2011,
Rating of Sound and Vibration for Refrigerant Compressors
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 540-2004: Performance Rating of Positive Displacement Refrigerant Compressors and Compressor Units
Standard Scope
This standard establishes a single set of testing and rating requirements for determining mass flow rate, power input, and efficiency for positive displacement refrigerant compressors and compressor units; whereby, equipment performance ratings can be compared from product to product.
Free Download:
ANSI/AHRI Standard 540-2004
© 2004, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 550/590 (I-P)-2011 with Addendum 1: Performance Rating of Water-Chilling and Heat Pump Water-Heating Packages Using the Vapor Compression Cycle
Standard Scope
This standard establishes a single set of testing and rating requirements for determining capacities, energy efficiencies (power input per ton, EER), water pressure drop, IPLV (integrated part load value), and NPLV (non-standard part load value) for water chilling packages using the vapor compression cycle; whereby, equipment performance ratings can be compared from product to product. The standard applies to chilling packages including one or more hermetic or open drive compressors (centrifugal, rotary screw, scroll, reciprocating, or other types), equipped with either water-cooled, air-cooled, evaporative-cooled condensers or supplied without a condenser.
Free Downloads:
ANSI/AHRI Standard 550/590 (I-P)-2011 with Addendum 1
,
Appendix G Pressure Drop Adjustments
Calibration Worksheet
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 551/591 (SI)-2011 with Addendum 1: Performance Rating of Water-Chilling and Heat Pump Water-Heating Packages Using the Vapor Compression Cycle
Standard Scope:
This standard establishes a single set of testing and rating requirements for determining capacities, energy efficiencies (power input per ton, COP), water pressure drop, IPLV (integrated part load value), and NPLV (non-standard part load value) for water chilling packages using the vapor compression cycle; whereby, equipment performance ratings can be compared from product to product. The standard applies to chilling packages including one or more hermetic or open drive compressors (centrifugal, rotary screw, scroll, reciprocating, or other types), equipped with either water-cooled, air-cooled, evaporative-cooled condensers or supplied without a condenser.
Free Downloads:
ANSI/AHRI 551/591 (SI)-2011 with Addendum 1,
Appendix G Pressure Drop Adjustments
Calibration Worksheet
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 560-2000: Absorption Water Chilling and Water Heating Packages
Standard Scope
This standard establishes a single set of testing and rating requirements for determining capacities, water pressure drops, integrated part load values (IPLV's) and application part load values (APLV's) for absorption water-chilling and water-heating packages; whereby, equipment performance ratings can be compared from product to product. This standard applies to single-effect steam and hot fluid operated water chilling units, double-effect steam and hot fluid operated water chilling units, and double-effect direct-fired (natural gas, oil, LP gas) water chilling/heating units. Also included are multiple-effect and multi-loop cycle absorption water chilling/heating units.
Free Download:
ANSI/AHRI Standard 560-2000
© 2000, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 575-2008: Method of Measuring Machinery Sound Within an Equipment Space
Standard Scope
This standard establishes a uniform method of measuring and recording the sound pressure level of machinery installed in a mechanical equipment space. The standard applies to water chilling systems, pumps and similar operating machines and parts thereof, which for reasons of size, or operating characteristics are more practically evaluated in situ. It is not the intent of the standard to be used for the sound rating of equipment.
Free Download:
ANSI/AHRI Standard 575-2008
© 2009, by Air-Conditioning, Heating and Refrigeration Institute
ANSI/AHRI 580-2009: Non-Condensable Gas Purge Equipment For Use With Low Pressure Centrifugal Liquid Chillers
Standard Scope
This standard applies to non-condensable gas Purge Equipment for use with Low Pressure Centrifugal Liquid Chillers as defined in Section 3. This standard defines general equipment requirements, test methods and analysis techniques used to determine the performance rating for Purge Equipment that remove Non-Condensable Gases from Low Pressure Centrifugal Liquid Chillers. This Purge Equipment is typically used in conjunction with chillers which operate with at least a portion of the system below atmospheric pressure.
Free Download:
ANSI/AHRI Standard 580-2009
© 2009, by Air-Conditioning, Heating and Refrigeration Institute
ANSI/AHRI 610-2004: Performance Rating of Central System Humidifiers for Residential Applications
Standard Scope
This standard establishes a single set of requirements for the testing and rating of humidification capacity, air pressure drop, and energy consumption and energy efficiency (where used) for central system humidifiers used in residential applications. Central system humidifiers are defined as humidifiers intended to be installed on ducted residential heating/cooling central systems.
Free Download:
ANSI/AHRI Standard 610-2004
© 2004, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 620-2004: Performance Rating of Self-Contained Humidifiers for Residential Applications
Standard Scope
This standard establishes a single set of requirements for the testing and rating of humidification capacity, power input, and energy input of supplementary heat (where used) for self-contained humidifiers for residential applications. Self-contained humidifiers are defined as humidifiers intended to be installed with a water make-up line and/or drain and electrical services - it may or may not be installed within the humidified space.
Free Download:
ANSI/AHRI Standard 620-2004
© 2004, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 640-2005: Performance Rating of Commercial and Industrial Humidifiers
Standard Scope
This standard establishes a single set of requirements for the testing and rating of humidification capacity, power input, and energy input of supplementary heat (where used) for humidifiers used in commercial and industrial applications. Devices of the following types are included: atomizing, electric resistance steam generators, electrode steam generators, heat exchangers, infrared, steam injection, and wetted media.
Free Download:
ANSI/AHRI Standard 640-2005
© 2005, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 680 (I-P)-2009: Performance Rating Residential Air Filter Equipment
Standard Scope
This standard applies to factory-made Air Filter Equipment and Air Filter Media, as used in such equipment, for removing particulate matter, when used in environmental conditioning of inhabited spaces in residential facilities.
Free Download:
ANSI/AHRI Standard 680 (I-P)-2009
© 2009, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 681 (SI)-2009: Performance Rating Residential Air Filter Equipment
Standard Scope
This standard applies to factory-made Air Filter Equipment and Air Filter Media, as used in such equipment, for removing particulate matter, when used in environmental conditioning of inhabited spaces in residential facilities.
Free Download:
ANSI/AHRI Standard 681 (SI)-2009
© 2009, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 710 (I-P) - 2009: Performance Rating of Liquid-Line Driers
Standard Scope
This standard establishes a single set of requirements for the testing and rating of water capacity and refrigerant flow capacity for driers to be used in the liquid lines of refrigerating and air-conditioning systems; whereby, equipment performance can be compared from product to product.
Free Download:
ANSI/AHRI Standard 710 (I-P)-2009
© 2009, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 711 (SI)-2009: Performance Rating of Liquid-Line Driers
Standard Scope
This standard establishes a single set of requirements for the testing and rating of water capacity and refrigerant flow capacity for driers to be used in the liquid lines of refrigerating and air-conditioning systems; whereby, equipment performance can be compared from product to product.
Free Download:
ANSI/AHRI Standard 711 (SI)-2009
© 2009, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 730-2005: Flow Capacity Rating of Suction-Line Filters and Suction-Line Filter-Driers
Standard Scope
This standard establishes a single set of requirements for the testing and rating of ARI standard capacity rating and refrigerant flow rate for refrigerant suction-line filters and filter-driers; whereby, equipment performance can be compared from product to product. The standard covers suction-line filters and suction-line filter-driers in refrigeration and air-conditioning systems.
Free Download:
ANSI/AHRI Standard 730-2005
© 2005, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 750-2007: Thermostatic Refrigerant Expansion Valves
Standard Scope
This standard applies to Thermostatic Refrigerant Expansion Valves for use with refrigerants listed in 2.1.1 at evaporator temperatures between +50ºF [10ºC] and -40ºF [-40ºC].
Free Download:
ANSI/AHRI Standard 750-2007
© 2007, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 760-2007: Performance Rating of Solenoid Valves for Use with Volatile Refrigerants
Standard Scope
This standard applies to Solenoid Valves for use with Volatile Refrigerants as defined in Section 3.
Free Download:
ANSI/AHRI Standard 760-2007
© 2007, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 770-2007: Performance Rating of Refrigerant Pressure Regulating Valves
Standard Scope
This standard establishes a single set of requirements for the testing and rating of capacity for refrigerant pressure regulating valves for use with refrigerants R-12, R-22, R-134a, R-502, R-404A, and R-717. The standard applies to refrigerant pressure regulating valves controlling volatile refrigerant flow whose primary response is to pressure.
Free Download:
ANSI/AHRI Standard 770-2007
© 2007, by Air-Conditioning, Heating and Refrigeration Institute
ANSI/AHRI 820 (I-P)-2012: Performance Rating of Ice Storage Bins
Standard Scope
This standard establishes a single set of requirements for the testing and rating of capacity and efficiency for ice storage bins; whereby, storage bin performance ratings can be compared from product to product.
Free Download:
ANSI/AHRI 820 (I-P)-2012:
Performance Rating of Ice Storage Bins
© 2012, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 821 (SI)-2012: Performance Rating of Ice Storage Bins
Standard Scope
This standard establishes a single set of requirements for the testing and rating of capacity and efficiency for ice storage bins; whereby, storage bin performance ratings can be compared from product to product.
Free Download:
AHRI 821 (SI)-2012: Performance Rating of Ice Storage Bins
© 2012, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 850-2004: Performance Rating of Commercial and Industrial Air Filter Equipment
Standard Scope
This standard applies to factory-made Air Filter Equipment and Air Filter Media as used in such equipment, for removing particulate matter, when used in environmental conditioning of inhabited spaces in commercial and industrial facilities.
Free Download:
ANSI/AHRI Standard 850-2004
© 2004, by Air-Conditioning and Refrigeration Institute
ANSI/AHRI 870-2005: Performance Rating of Direct Geoexchange Heat Pumps
Standard Scope
This standard establishes a single set of requirements for the testing and rating of cooling and heating capacities, EER, and COP for residential, commercial, and industrial direct geoexchange heat pumps; whereby, equipment performance ratings can be compared from product to product.
Free Download:
ANSI/AHRI Standard 870-2005
© 2005, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI Standard 880 (I-P) - 2011 with Addendum 1: Performance Rating of Air Terminals
Standard Scope
The purpose of this standard is to establish for Air Terminals: definitions; classifications; test requirements;rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions. This standard applies to air control devices used in air distribution systems.
Free Download:
ANSI/AHRI Standard 880 (I-P) - 2011 with Addendum 1:
Performance Rating of Air Terminals
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI Standard 881 (SI)-2011 with Addendum 1: Performance Rating of Air Terminals
Standard Scope
The purpose of this standard is to establish for Air Terminals: definitions; classifications; test requirements;rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions. This standard applies to air control devices used in air distribution systems.
Free Download:
ANSI/AHRI Standard 881 (SI)-2011 with Addendum 1:,
Performance Rating of Air Terminals
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 900 (I-P)-2010, Performance Rating of Thermal Storage Equipment Used for Cooling
Standard Scope
This standard applies to Thermal Storage Equipment used for cooling which may be charged and discharged with any of a variety of heat transfer fluids. The equipment, as further described in Sections 3 and 4, may be fully factory assembled; assembled on site from factory supplied components; or field erected in accordance with pre-established design criteria.
Free Download:
ANSI/AHRI Standard 900 (I-P)-2010
© 2010, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 901 (SI)-2010, Performance Rating of Thermal Storage Equipment Used for Cooling
Standard Scope
This standard applies to Thermal Storage Equipment used for cooling which may be charged and discharged with any of a variety of heat transfer fluids. The equipment, as further described in Sections 3 and 4, may be fully factory assembled; assembled on site from factory supplied components; or field erected in accordance with pre-established design criteria.
Free Download
:
ANSI/AHRI Standard 901 (SI)-2010
Copyright 2010, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 910-2011: Performance Rating of Indoor Pool Dehumidifiers
Standard Scope
This standard establishes a single set of requirements for the testing and rating of moisture removal capacity and moisture removal efficiency of indoor pool dehumidifiers; whereby, equipment performance ratings can be compared from product to product. The standard also requires design of the product so as to meet the requirements of a maximum operating conditions test and an insulation efficiency test.
Free Download:
AHRI Standard 910-2011
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1060 (I-P)-2011, Performance Rating of Air-to-Air Heat Exchangers for Energy Recovery Ventilation Equipment
Standard Scope
This standard establishes a single set of requirements for the testing and rating of air flow rate, sensible, latent, and total effectiveness, and pressure drop of air-to-air energy recovery ventilation equipment; whereby, equipment performance ratings can be compared from product to product.
Free Download:
ANSI/AHRI Standard 1060 (I-P)-2011,
Performance Rating of Air-to-Air Heat Exchangers for Energy Recovery Ventilation Equipment
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1061 (SI)-2011, Performance Rating of Air-to-Air Heat Exchangers for Energy Recovery Ventilation Equipment
Standard Scope
This standard establishes a single set of requirements for the testing and rating of air flow rate, sensible, latent, and total effectiveness, and pressure drop of air-to-air energy recovery ventilation equipment; whereby, equipment performance ratings can be compared from product to product.
Free Download:
ANSI/AHRI Standard 1061 (SI)-2011,
Performance Rating of Air-to-Air Heat Exchangers for Energy Recovery Ventilation Equipment
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1120-2012: Acoustical Test Methods and Sound Power Rating Procedures for Transport Refrigeration Equipment
Standard Scope
This standard applies to factory-made transport refrigeration equipment.
Free Download:
ANSI/AHRI 1120-2012:
Acoustical Test Methods and Sound Power Rating Procedures for Transport Refrigeration Equipment
© 2012 Air Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1140-2012: Sound Quality Evaluation Procedures For Air-Conditioning and Refrigeration Equipment
Standard Scope
This standard applies to factory-made, residential and commercial air conditioning as well as transport refrigeration equipment.
Free Download:
ANSI/AHRI 1140-2012:
Sound Quality Evaluation Procedures For Air-Conditioning and Refrigeration Equipment
© 2012, by Air-Conditioning, Heating and Refrigeration Institute
ANSI/AHRI 1160 (I-P)-2009, Performance Rating of Heat Pump Pool Heaters
Standard Scope
This standard establishes definitions, classifications, test requirements, rating requirements, minimum data requirements for Published ratings, operating requirements, marking and nameplate data, and conformance conditions for heat pump pool heaters.
Free Download:
ANSI/AHRI Standard 1160 (I-P)-2009,
Performance Rating of Heat Pump Pool Heaters
© 2009, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1161 (SI)-2011, Performance Rating of Heat Pump Pool Heaters
Standard Scope
This standard establishes a single set of requirements for the testing and rating of cooling capacities and electric standby cooling capacities for mechanical transport refrigeration units employing forced-circulation air-coolers; whereby, equipment performance ratings can be compared from product to product.
Free Download:
ANSI/AHRI Standard 1161 (SI)-2011,
Performance Rating of Heat Pump Pool Heaters
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1200 (I-P)-2010: Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets
Standard Scope
This standard applies to the following manufacturers’ standard catalog Commercial Refrigerated Display Merchandisers and Storage Cabinets, provided that the cases are equipped and designed to work with electrically driven, direct expansion type systems:
Self-contained and Remote Commercial Refrigerated Display Merchandisers and Storage Cabinets
Open and Closed Commercial Refrigerated Display Merchandisers
Free Downloads:
ANSI/AHRI Standard 1200 (I-P)-2010
Interpretation 1 of ANSI/AHRI Standard 1200 (I-P) and 1201 (SI)-2010
Interpretation 2 of ANSI/AHRI Standard 1200 (I-P) and 1201 (SI)-2010
Interpretation 3 of ANSI/AHRI Standard 1200 (I-P) and 1201 (SI)-2010
Interpretation 4 of ANSI/AHRI Standards 1200 (I-P)-2010 and 1201 (SI)-2010
Interpretation 5 of ANSI.AHRI Standard 1200 (I-P) & 1201 (SI)-2010
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1201 (SI)-2010: Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets
Standard Scope
This standard applies to the following manufacturers’ standard catalog Commercial Refrigerated Display Merchandisers and Storage Cabinets, provided that the cases are equipped and designed to work with electrically driven, direct expansion type systems:
Self-contained and Remote Commercial Refrigerated Display Merchandisers and Storage Cabinets
Open and Closed Commercial Refrigerated Display Merchandisers
Free Downloads:
ANSI/AHRI Standard 1201 (SI)-2010
Interpretation 1 of ANSI/AHRI Standard 1200 (I-P) and 1201 (SI)-2010
Interpretation 2 of ANSI/AHRI Standard 1200 (I-P) and 1201 (SI)-2010
Interpretation 3 of ANSI/AHRI Standard 1200 (I-P) and 1201 (SI)-2010
Interpretation 4 of ANSI/AHRI Standards 1200 (I-P)-2010 and 1201 (SI)-2010
Interpretation 5 of ANSI.AHRI Standard 1200 (I-P) & 1201 (SI)-2010
© 2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1210 (I-P)-2011: Performance Rating of Variable Frequency Drives
Standard Scope:
This standard applies, within the heating, ventilating, air-conditioning and refrigeration (HVACR) context, to VFDs used in the control of asynchronous induction motors. The range includes all those found within a building including: low voltage (= 600 V) and drives that are stand alone, not mechanically integrated into motors.
Free Download:
ANSI/AHRI Standard 1210 (I-P)-2011
©2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1211 (SI)-2011: Performance Rating of Variable Frequency Drives
Standard Scope:
This standard applies, within the heating, ventilating, air-conditioning and refrigeration (HVACR) context, to VFDs used in the control of asynchronous induction motors. The range includes all those found within a building including: low voltage (= 600 V) and drives that are stand alone, not mechanically integrated into motors.
Free Download:
ANSI/AHRI Standard 1211 (SI)-2011
©2011, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1230-2010 with Addendum 1: Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment
Standard Scope
This standard covers matched variable refrigerant flow Multi-Split Air Conditioners and Multi-Split Heat Pumps using distributed refrigerant technology with cooling and heating capacities for outdoor units from 12,000 Btu/h [3508 W] to 300,000 Btu/h [90,000 W] and indoor units from 5,000 Btu/h [1,000W] to 60,000 Btu/h [20,000 W]. Each indoor unit is designed to condition a single zone.
Free Download:
ANSI/AHRI Standard 1230-2010 with Addendum
© 2010, by Air-Conditioning, Heating and Refrigeration Institute
ANSI/AHRI 1250 (I-P)-2009: Performance Rating of Walk-In Coolers and Freezers
Standard Scope
This standard applies to mechanical refrigeration equipment consisting of an integrated single package refrigeration unit, or separate Unit Cooler and condensing unit sections, where the condensing section can be located either outdoor or indoor.
Free Download:
ANSI/
AHRI Standard 1250 (I-P)-2009
© 2009, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1251 (SI)-2009: Performance Rating of Walk-In Coolers and Freezers
Standard Scope
This standard applies to mechanical refrigeration equipment consisting of an integrated single package refrigeration unit, or separate Unit Cooler and condensing unit sections, where the condensing section can be located either outdoor or indoor.
Free Download:
A
NSI/AHRI Standard 1251 (SI)-2009
© 2009, by Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1270 (I-P) – 2011, Requirements for Seismic Qualification of HVACR Equipment
Standard Scope
This standard describes the methods for equipment qualification and the process to determine equipment Seismic Capacity.
Free Download:
ANSI/AHRI Standard 1270 (I-P) – 2011
©2011 Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1271 (SI)-2011, Requirements for Seismic Qualification of HVACR Equipment
Standard Scope
This standard describes the methods for equipment qualification and the process to determine equipment Seismic Capacity.
Free Download:
ANSI/AHRI Standard 1271 (SI)-2011
©2011 Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1320 (I-P) – 2011, Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets for Use With Secondary Refrigerants
Standard Scope
This standard applies to the following Commercial Refrigerated Display Merchandisers and Storage Cabinets, provided that the cases are equipped and designed to work with electrically driven, medium-temperature, single-phase secondary coolant systems: Remote Commercial Refrigerated Display Merchandisers and Storage Cabinets as well as Open and Closed Commercial Refrigerated Display Merchandisers.
Free Download:
ANSI/AHRI Standard 1320 (I-P) – 2011
©2011 Air-Conditioning, Heating, and Refrigeration Institute
ANSI/AHRI 1321 (SI) – 2011, Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets for Use With Secondary Refrigerants
Standard Scope
This standard applies to the following Commercial Refrigerated Display Merchandisers and Storage Cabinets, provided that the cases are equipped and designed to work with electrically driven, medium-temperature, single-phase secondary coolant systems: Remote Commercial Refrigerated Display Merchandisers and Storage Cabinets as well as Open and Closed Commercial Refrigerated Display Merchandisers.
Free Download:
ANSI/AHRI Standard 1321 (SI) – 2011
©2011 Air-Conditioning, Heating, and Refrigeration Institute
ASHRAE's Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings
Standard Scope
AHRI closely follows ASHRAE's Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings. Standard 90.1 provides minimum requirements for the design of energy efficient buildings. The first edition of ASHRAE Standard 90.1 was published in 1975 and revisions were approved in 1980, 1989, 1999. Since 1999, the standard has been updated every three years. The 90.1 standard is referenced in the International Energy Conservation Code (IECC) as well as in the National Fire Protection Association (NFPA) 5000 Building Construction and Safety Code. In addition, states are required, under the energy policy act (EPACT) of 1992, to adopt a building energy code as or more stringent than ASHRAE 90.1.
AHRI monitors the status of ASHRAE 90.1 activity throughout all states. Most states adopt ASHRAE 90.1 or the International Energy Conservation Code as their building energy code. However, few states have no energy codes.
For information on ASHRAE Standard 90.1
, visit ASHRAE's Web site at
www.ashrae.org
or call them at 1-800-527-4723.
Free Download:
ASHRAE Standard 90.1
ASHRAE/ANSI/AHRI/ISO Standard 13256-1&2: 1998
The standards listed below may be ordered online through the
ASHRAE bookstore
.
ANSI/AHRI/ASHRAE/ISO Standard 13256-1 Water-to-Air and Brine-to-Air Heat Pumps — Testing and Rating for Performance
ANSI/AHRI/ASHRAE/ISO Standard 13256-2 Water-to-Water and Brine-to-Water Heat Pumps — Testing and Rating for Performance
Baseboard Radiation Testing and Rating Standard
Free Download:
Baseboard Radiation Testing and Rating Standard
NOTE:
This is a large file. Download may take a few minutes depending on your connection speed.
Finned Tube (Commercial) Testing and Rating Standard
Free Download:
Finned Tube (Commercial) Testing and Rating Standard
NOTE:
This is a large file. Download may take a few minutes depending on your connection speed.
Hydronics Testing Standard BTS 2000
Free Download:
Hydronics Testing Standard BTS 2000
Indirect-Fired Water Heater Testing Standard
Free Downloads:
Indirect-Fired Water Heater Testing Standard
Indirect-Fired Water Heater Testing Standard-Supplement